![]() ![]() This problem can occur in anaerobic treatment systems owing to a malfunctioning aeration mechanism or a high water level in the aeration tank, among other things. A high amount of sludge in the system can also be a contributing factor to this problem, which can be resolved by septic tank cleaning. It is also possible for the water level to rise due to mechanical faults with the air compressor, float switch, or other components. The leach field can get blocked with effluent, which can cause the water level to rise as a result. If the pump fails, the amount of water in the tank will rise as a result. Pumps are used in certain septic tanks to transport effluent to secondary wastewater treatment facilities. This reduces the rate at which wastewater exits the system, resulting in an increase in the volume of water in the septic tank. The effluent filters must be cleaned every six months, or sediments would collect in the filters and cause them to clog. It’s possible that the effluent filter is blocked. Is your septic system sounding the alarm? Allow our septic system professionals to assist you. If a large amount of water is utilized in between pumping cycles, the water has nowhere to go and will continue to rise within the tank until it is exhausted. The timer regulates the periods during which the pump is allowed to discharge wastewater from the system. On most septic tanks, a timer has been built, which permits the pump to discharge wastewater into the leach field at predetermined intervals. It is also possible that the problem is caused by a high level of sludge in the tank, in which case septic tank cleaning is usually sufficient to resolve the situation. As a result, if your alarm goes off or if you notice a red light on your alarm, this might signal that the water level is greater than typical. ![]() They are intended to notify the user if the water level becomes too high or excessively low. Septic alarm systems are designed to keep track of the water levels in the septic tank. Don’t forget to move it back to the “on” position once the problem is fixed. Turn the toggle switch on your alarm box to the “off” position. Confirm that all exposed equipment and lines are clean and in proper working order.Find your white, rectangular shaped alarm box which is usually located near the access to your crawl space and is where the noise is originating from.If the breaker connected to your Hoot system has tripped, set it back in place and see if the alarm turns off. Here are a few things you can check for yourself: You'll notice the status light will stay illuminated even when the sound is off and will stay on until the issue that triggered the alarm is solved. NOTE: Pressing the silence button stops the Hoot alarm sound only. The sound may be loud, but you can silence the audio alarm by pressing the silence button on the Hoot Controller door. If your Hoot alarm turns on, don't panic - it is usually not an emergency. Our Hoot System has two types of alarms: Visual - A red light illuminates when the alarm triggers and Audio - A constant, high-pitched buzz that sounds when the alarm triggers This lets homeowners know when there is a problem with their system. ![]() Alarms are required on any type of septic treatment system that has a pump attached to it. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |